Typical Applications:

Use For Timed Control Of:

Signs

Area Lighting

Exclusive Features:

On at Dusk Off After Selectable Time of Percent of Night

Zero Crossover Load Switching for Extended Relay Life

Double-Sided Plated-Through Circuit Board (DSPT) for durability and relibility

Built-in Microprocessor for precision and consistency

Full Wave Rectification

Dual Zener Diodes + Integrated Voltage Regulator

High Impact Thermoplastic Base

Solid Brass Contact Blades

UV Stabilized Permanent Color, High Impact Resistant Polypropylene Cover

 

SouthConn Technologies Logo
SouthConn Technologies, Inc.

Credit Cards

DarkSky

Twist-Lock Electronic Photocontrol:
Selectable Timed Control

Turns On at Dusk,
Then Off After Selectable
Time or Percent of Night

For Convenient Selectable
Timed Control of
Outdoor Lighting

 
RT8394
Configuration

On at Dusk
Off after Selectable Turn Off Setting

Turn Off setting is selected from the following:
Turn Off 2, 3, 4, 5, 6 or 7 hours after dusk;
Turn Off after 40% or 50% of Night;
Always On; Dusk to Dawn

Nominal Voltage 50/60 Hz
120/208/240/277

Voltage Range

105-305
Fail Mode
On
Load Rating
1000 Watt Tungsten / 1800 VA Ballast
Operating Temperature
-40C to +70C (-40F to +158F)
Photocell
Encapsulated Silicon Phototransistor
Dielectric Strength
5000 Volts between current carrying parts and metal surfaces
Surge Protection
320 Joule MOV / 10,000 amp surge current
Power Consumption
0.5 watts @ 120 V
Time Delay Off (Instant On)
5 seconds
Operating Light Levels (Standard Settings)
Turn On 3.0 FC ± .25 / Turn Off by 3.0 FC
(Off:On Ratio = 1:1)
ANSI Color Coded Cover
Black

Selectable Timed Control DiagramSimple Setup utillizes selector switch conveniently located in the photocontrol base

Set Turn-Off Selector switch to the number corresponding to desired opertion.

1 Always On
2 thru 7 Turn Off 2, 3, 4, 5, 6 or 7 hours after dusk (respectively)
8 Turn Off after 40% of night
9 Turn Off after 50% of night
0 Lights operate from dusk to dawn

 

 

 

 

 

 